Handyscope HS3 Software specifications
| Oscilloscope |
| Display channels |
CH1, CH2, CH1 and CH2 |
| Display mode |
| Envelope mode |
On/Off |
| Averaging |
1..256 measurements |
| Math mode |
CH1+CH2, CH1-CH2, CH2-CH1 |
| Invert |
Normal, Invert |
| Sensitivity |
200mV, 400mV, 800mV, 2V, 4V, 8V, 20V, 40V, 80V
full scale |
| Vertical magnification |
0.25x to 10x (8 bit) 0.25x to 10x (12
bit) 0.25x to 40x (14 bit) 0.25x to 160x (16 bit) |
| Input coupling |
AC/DC |
| Time base maximum |
75.8 days/div |
| Time base magnifying |
1x to > 80x |
| Record length |
131040 samples |
| Record view scroll bar gain |
1 to 125 |
| |
| Trigger mode |
free run, delayed run, auto, single, edge
triggered, window, peak, external |
| Trigger system |
two digital trigger levels, 4096
positions |
| Trigger source |
CH1, CH2, External, Keyboard and Master |
| Trigger level |
0-100% full input range |
| Trigger level resolution |
0.025 % full scale |
| Pre trigger |
1 to 131040 samples |
| Post trigger |
1 to 131040 samples |
| Trigger delay |
1 to 131040 samples |
| Trigger hysteresis |
0-100% full input range |
| Trigger hysteresis resolution |
0.025 % full scale |
| |
| Auto disk measuring |
1 to 1000 files |
| Auto setup |
connect and show |
| Zooming |
mouse windows control, gain vertical and gain
horizontal |
| Cursor system |
two cursor pairs, auto tracking, auto correct
points |
| Cursor mode |
large cursors, small cursors |
| Cursor measurements |
rise time left rise time right sample
time left sample time right sample time difference cursor
frequency Voltage left Voltage right Voltage
difference slew rate left slew rate right phase difference
in Degrees, Radials or cos() |
| |
| Voltmeter |
| Display channels |
CH1, CH2, CH1 and CH2 |
| Display size |
user selectable |
| Number of displays |
1 to 6 user selectable |
| Frequency range |
10 Hz to 20 MHz (model HS3-100MHz) 10 Hz to
10 MHz (model HS3-50MHz) 10 Hz to 5 MHz (model HS3-25MHz) 10
Hz to 2 MHz (model HS3-10MHz) 10 Hz to 1 MHz (model
HS3-5MHz) |
| Full scale reading |
2000 counts |
| Measurements |
True RMS, Peak-Peak, Mean, Max, Min, dBm,
Power, Crest, Frequency, Duty cycle, Momentary value |
| Display mode |
CH1, CH2, CH1*CH2, CH1/CH2, CH2/CH1, CH1-CH2,
CH2-CH1, CH1+CH2, >then Hi, <then Lo, ><COMP,
<> HI LO, MAX, MIN, LOG(CH1/CH2), LOG(CH2/CH1) |
| Measure units |
Volt, Amp, °C, °F, Watt, %, Meter, Coulomb,
Hertz, Bar, user defined |
| Relative |
CH1, CH2, user defined value |
| Sound settings |
No sound, 100Hz, 200Hz, 500Hz, 1kHz, 2kHz, and
10kHz |
| Data storage |
direct on paper, on disk, on network |
| Acquisition hysteresis |
user defined value |
| |
| Transient recorder |
| Measuring channels |
CH1, CH2, CH1 and CH2 |
| Measure time between to points |
0.01 sec to 500 sec |
| Measure time span |
758.4 days |
| Measure mode |
roll mode or scan mode |
| Cursor readout |
see oscilloscope |
| Time reference |
time of start, time of measuring, time
difference |
| |
| Spectrum analyzer |
| Display channels |
CH1, CH2, CH1 and CH2 |
| Display mode |
max mode, standard mode |
| Measuring mode |
single shot, continuous |
| Sensitivity |
200mV, 400mV, 800mV, 2V, 4V, 8V, 20V, 40V, 80V
full scale |
| Vertical magnification |
0.25x to 10x (8 bit) 0.25x to 10x (12
bit) 0.25x to 40x (14 bit) 0.25x to 160x (16 bit) |
| Input coupling |
AC/DC |
| Frequency axis |
Logarithmic, linear, octaves or third
octave |
| Octave range |
22.1Hz to 22.6 kHz |
| Frequency range |
DC to 50 MHz (model HS3-100MHz) DC to 25
MHz (model HS3-50MHz) DC to 12.5 MHz (model HS3-25MHz) DC to 5
MHz (model HS3-10MHz) DC to 2 MHz (model HS3-5MHz) |
| Record length |
32 to 32768 frequency components |
| Window functions |
rectangular, Hanning, Hamming, Bartlett,
Blackman, Parzen, Welch, Blackman-Harris |
| Averaging |
1 to 256 measurements |
| Cursor readout |
see oscilloscope |
| Total Harmonic Distortion |
1 to 100 harmonics |
| |
| Arbitrary Waveform Generator |
| Signal sources |
sinewave, triangle, square, DC, white noise,
user defined |
| Sweep |
locked on spectrum analyzer |
| Frequency |
0.01 Hz to 2 MHz |
| Amplitude |
0 .. ±12 Volt, max 50 mAmp |
| Symmetry |
1 % to 99 % |
| DC offset |
0 .. ±12 Volt |
| Presets |
8 positions |
| Record length |
256 Kwords |
| |
|